Improved Lunar Intrusion Detection Algorithm for the CrIS Sensor Data Record
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

The NOAA IR serves as an archival repository of NOAA-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by NOAA or funded partners. As a repository, the NOAA IR retains documents in their original published format to ensure public access to scientific information.
i

Improved Lunar Intrusion Detection Algorithm for the CrIS Sensor Data Record

Filetype[PDF-2.43 MB]



Details:

  • Journal Title:
    IEEE Transactions on Geoscience and Remote Sensing
  • Personal Author:
  • NOAA Program & Office:
  • Description:
    As one of the calibration reference targets used to calibrate the cross-track infrared sounder (CrIS) earth scene (ES) measurements, the stable deep space (DS) reference spectrum in the 30-scan DS calibration moving window is very important for the accuracy of the calibrated ES radiances. The DS view changes when the lunar radiation intrudes into the observation field of view (FOV). In the original CrIS lunar intrusion (LI) detection algorithm implemented in the operational ground processing system, the contaminated DS spectra were not effectively removed from the DS moving window due to large threshold values and the assumption that the first DS spectrum in the moving window was not contaminated. As a result, inaccurate, degraded, or invalid ES radiances were produced in the operational CrIS sensor data record (SDR) during LI events. In this article, an improved LI detection algorithm is developed and implemented into the operational system. First, the new algorithm efficiently finds a contamination-free DS spectrum in the DS 30-scan calibration moving window to use as the reference spectrum. Second, based on the phase characteristics of the complex raw DS spectra during LI events, the LI band-dependent thresholds were derived to effectively reject the contaminated DS spectra and to make the valid DS window size consistent among the three CrIS bands. The new LI algorithm implemented in the operational system shows a successful detection and removal of all the lunar-contaminated DS spectra in the DS moving window, resulting in an improved calibration of ES radiances during LI events.
  • Source:
    IEEE Transactions on Geoscience and Remote Sensing, 58(2), 1134-1145
  • DOI:
  • ISSN:
    0196-2892;1558-0644;
  • Format:
  • Publisher:
  • Document Type:
  • Rights Information:
    Accepted Manuscript
  • Rights Statement:
    The NOAA IR provides access to this content under the authority of the government's retained license to distribute publications and data resulting from federal funding. While users may legally access this content, the copyright owners retain rights that govern the reproduction, redistribution, and re-use of this work. The user is solely responsible for complying with applicable copyright law.
  • Compliance:
    Submitted
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at repository.library.noaa.gov

Version 3.27.1