Characterization of Long-Term Stability of Suomi NPP Cross-Track Infrared Sounder Spectral Calibration
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

The NOAA IR serves as an archival repository of NOAA-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by NOAA or funded partners. As a repository, the NOAA IR retains documents in their original published format to ensure public access to scientific information.
i

Characterization of Long-Term Stability of Suomi NPP Cross-Track Infrared Sounder Spectral Calibration

Filetype[PDF-2.29 MB]



Details:

  • Journal Title:
    IEEE Transactions on Geoscience and Remote Sensing
  • Personal Author:
  • NOAA Program & Office:
  • Description:
    Since early 2012, the cross-track infrared sounder (CrIS) onboard the Suomi National Polar-Orbiting Partnership satellite has continually provided the hyperspectral infrared observations for profiling atmospheric temperature, moisture, and greenhouse gases. The CrIS radiance data are also directly assimilated into global numerical weather prediction models to improve the medium-range forecasts. These important applications require accurate CrIS calibration. Since CrIS radiometric accuracy depends on the accurate spectral calibration, it is important to reduce the spectral uncertainty and increase the calibration stability for weather and climate applications. In this paper, the accuracy of CrIS spectral calibration and its stability are assessed using the operational sensor data record (SDR) data generated by the interface data processing segment (IDPS). A spectral validation method is developed and applied to clear scene data over ocean from September 22, 2012, to April 19, 2016. It is shown that CrIS metrology laser wavelength varies within 3 ppm, as measured by the Neon calibration subsystem. While the current CrIS operational algorithm is designed to have a spectra error less than 2 ppm, the actual spectral errors are about 4 ppm due to the IDPS software bugs. A new correction method is applied to fix the bugs and to further improve CrIS spectral calibration. It is found that the CrIS spectral calibration accuracy is less than 1 ppm in both normal and full spectral resolution SDR data sets.
  • Source:
    IEEE Transactions on Geoscience and Remote Sensing, 55(2), 1147-1159
  • DOI:
  • ISSN:
    0196-2892;1558-0644;
  • Format:
  • Publisher:
  • Document Type:
  • Funding:
  • Rights Information:
    Accepted Manuscript
  • Rights Statement:
    The NOAA IR provides access to this content under the authority of the government's retained license to distribute publications and data resulting from federal funding. While users may legally access this content, the copyright owners retain rights that govern the reproduction, redistribution, and re-use of this work. The user is solely responsible for complying with applicable copyright law.
  • Compliance:
    Submitted
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at repository.library.noaa.gov

Version 3.27.1