An Analysis of the Performance of the Houston Lightning Mapping Array During an Intense Period of Convection During Tropical Storm Harvey
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

An Analysis of the Performance of the Houston Lightning Mapping Array During an Intense Period of Convection During Tropical Storm Harvey

  • 2021

  • Source: Journal of Geophysical Research: Atmospheres, 126(3)
Filetype[PDF-8.22 MB]


Select the Download button to view the document
This document is over 5mb in size and cannot be previewed

Details:

  • Journal Title:
    Journal of Geophysical Research: Atmospheres
  • Personal Author:
  • Description:
    Extreme lightning activity (∼300,000 flashes) was observed by the Houston Lightning Mapping Array (HLMA) network during Tropical Storm Harvey on August 26, 2017–August 27, 2017. There was an overall weak correlation between the lightning flash and precipitation rates (R = 0.14; p ∼ 0.17) likely due to feeder bands transitioning between deep and shallow convection. The peak precipitation rate (14.2 mm hr−1) lagged the peak lightning flash rate (∼18,000 flashes [30 min]−1) by 7 h. Adjusting for the lag, the correlation increased to 0.71 (p < 0.01) indicating a relationship between the uptick in lightning activity in the convective feeder bands and the resulting heavy precipitation during episodes of shallow convection. Peak lightning flash extent densities of 12.4 km−2 min−1 were spatially collocated with precipitation rates exceeding 9 mm hr−1. NEXRAD reflectivity data featured 30 dBZ echo heights in excess of 10 km that were collocated with peak lightning flash extent densities exceeding 3 km−2 min−1. The NEXRAD specific phase (kdp) and differential phase (Zdr) dual‐polarization products were highest (≥2° km−1 and dB) below the melting layer (4.6 km) indicating heavy precipitation and strong updrafts. Negative kdp and Zdr values (≤−0.15° km−1 and dB) collocated with the peak lightning flash extent density altitudes indicated ice particle generation which likely augmented the charge separation process. This is likely the first time a major tropical cyclone has occurred within the confines of a lightning mapping array. The lightning data, when used synergistically with radar and precipitation data, can adequately quantify tropical convection exhibiting an elevated mixed‐phase depth.
  • Source:
    Journal of Geophysical Research: Atmospheres, 126(3)