Measurements of fugacity of carbon dioxide in seawater: An evaluation of a method based on infrared analysis.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Measurements of fugacity of carbon dioxide in seawater: An evaluation of a method based on infrared analysis.

Filetype[PDF-49.88 MB]


Select the Download button to view the document
This document is over 5mb in size and cannot be previewed

Details:

  • Description:
    An analysis system is described to measure the fugacity of CO2 (fCO2)1 in 500 mL of seawater (discrete samples) by infrared analysis. The unit has been used on oceanographic research cruises sponsored by the Ocean-Atmosphere Carbon Exchange Study (OACES) of NOAA since 1991 for a total of approximately 10,000 measurements. The precision of the analyses based on replicate samples during routine analysis is 0.2%. Precision is primarily limited by sample storage, and the difference between headspace gas and water CO2 concentrations prior to equilibration. The precision and accuracy of the instrument is estimated in several different ways. A preliminary side by side test of two different discrete fCO2 systems using an infrared (IR) analyzer and a gas chromatograph (GC) shows a variability of 0.8% without significant bias. For surface waters the discrete measurements are compared with measurements from a continuous flowing underway system which was deployed on all cruises. Select comparisons with fCO2 calculated from spectrophotometric pH and DIC (Total Dissolved Inorganic Carbon) measurements are performed. These comparisons are limited by uncertainty in the magnitude and the temperature dependence of the carbon and borate dissociation constants. Indirect comparisons are made with pCO2 measurements of Drs. Takahashi and Chipman of LDEO in the South Atlantic and equatorial Pacific (EqPac). Although the measurements were performed months (for the EqPac study in 1992) to years (for the South Atlantic study in 1989 and 1991) apart, some inferences can be made by normalizing the fCO2 values and by performing the comparison in property space. The comparison indicates that the precision of our system is comparable to that of the LDEO system. The surface values obtained from the LDEO system during EqPac are 1.5 to 3% lower. There is inconclusive evidence that some of the subsurface LDEO pCO2 values are lower as well. However, the comparison of subsurface values for the North Atlantic Deep Water in the South Atlantic study shows good agreement. Because of the current uncertainty in dissociation constants, there is no a priori way to determine which value is correct.