Calibration and field testing of cavity ring-down laser spectrometers measuring CH4, CO2, and delta(CH4)-C-13 deployed on towers in the Marcellus Shale region
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Calibration and field testing of cavity ring-down laser spectrometers measuring CH4, CO2, and delta(CH4)-C-13 deployed on towers in the Marcellus Shale region

Filetype[PDF-4.68 MB]



Details:

  • Journal Title:
    Atmospheric Measurement Techniques
  • Description:
    Four in situ cavity ring-down spectrometers (G2132-i, Picarro, Inc.) measuring methane dry mole fraction (CH4), carbon dioxide dry mole fraction (CO2), and the isotopic ratio of methane (delta(CH4)-C-13)were deployed at four towers in the Marcellus Shale natural gas extraction region of Pennsylvania. In this paper, we describe laboratory and field calibration of the analyzers for tower-based applications and characterize their performance in the field for the period January-December 2016. Prior to deployment, each analyzer was tested using bottles with various isotopic ratios, from biogenic to thermogenic source values, which were diluted to varying degrees in zero air, and an initial calibration was performed. Furthermore, at each tower location, three field tanks were employed, from ambient to high mole fractions, with various isotopic ratios. Two of these tanks were used to adjust the calibration of the analyzers on a daily basis. We also corrected for the cross-interference from ethane on the isotopic ratio of methane. Using an independent field tank for evaluation, the standard deviation of 4 h means of the isotopic ratio of methane difference from the known value was found to be 0.26% delta(CH4)-C-13. Following improvements in the field tank testing scheme, the standard deviation of 4 h means was 0.11 %, well within the target compatibility of 0.2 %. Round-robin style testing using tanks with near-ambient isotopic ratios indicated mean errors of 0.14 to 0.03% for each of the analyzers. Flask to in situ comparisons showed mean differences over the year of 0.02 and 0.08 %, for the east and south towers, respectively. Regional sources in this region were difficult to differentiate from strong perturbations in the background. During the afternoon hours, the median differences of the isotopic ratio measured at three of the towers, compared to the background tower, were 0.15 to 0.12% with standard deviations of the 10 min isotopic ratio differences of 0.8 %. In terms of source attribution, analyzer compatibility of 0.2% delta(CH4)-C-13 affords the ability to distinguish a 50 ppb CH4 peak from a biogenic source (at 60 %, for example) from one originating from a thermogenic source (35 %), with the exact value dependent upon the source isotopic ratios. Using a Keeling plot approach for the non-afternoon data at a tower in the center of the study region, we determined the source isotopic signature to be -31.2 +/- 1.9 %, within the wide range of values consistent with a deep-layer Marcellus natural gas source.
  • Source:
    Atmospheric Measurement Techniques, 11(3), 1273-1295.
  • Document Type:
  • Rights Information:
    CC BY
  • Compliance:
    Submitted
  • Main Document Checksum:
  • File Type:

Supporting Files

  • No Additional Files

More +

You May Also Like

Checkout today's featured content at repository.library.noaa.gov

Version 3.24