{"Bibliographic":{"Title":"No-moving parts anemometer design analysis program /\n\n*Front matter is located at back of the document. Please more those 3 pages to the front of the document prior to scanning. ","Authors":"","Publication date":"1977","Publisher":""},"Administrative":{"Date created":"08-20-2023","Language":"English","Rights":"CC 0","Size":"0000043690"},"Pages":["QC\nOF\nCOMMUNITY\n851\n.U6E4\nno.16\n*\nNOAA Technical Memorandum NWS EDL 16\n*\nAvenue\nWATER\nSTATES OF\nNO-MOVING PARTS ANEMOMETER DESIGN ANALYSIS\nPROGRAM\nSilver Spring, Md.\nOctober 1977\n/\nNational Weather\nnoaa\nNATIONAL OCEANIC AND\nService\nATMOSPHERIC ADMINISTRATION","ATMOSPHERIC\nDEPARTMENT\nNOAA\ny Series\nn\nent Laboratory of the Office of Systems Development designs, develops, and\nequipment, and subsystems to meet National Weather Service requirements, con-\nelating to environmental sensing and prototype models, and provides informa-\ncomments\nS.\nDEPARTMENT\nthe name or description of any product does not constitute an endorsement\nby\nf\nOF\nService. Use for publicity or advertising purposes of information from this\nroprietary products or the tests of such products is not authorized.\nNOAA Technical Memoranda in the National Weather Service Equipment Development Laboratory series\nfacilitate prompt distribution of EDL reports that may be preliminary in nature and that may be pub-\nlished formally elsewhere at a later date. Publication 1 is in the former series, Weather Bureau\nTechnical Notes (TN) ; publications 2 through 11 are in the former series, ESSA Technical Memoranda,\nWeather Bureau Technical Memoranda (WBTM). Beginning with EDL-12, publications are now part of the\nseries NOAA Technical Memoranda, National Weather Service (NWS).\nThe reports listed below are available from the National Technical Information Service, U.S. Depart-\nment of Commerce, Sills Bldg., 5285 Port Royal Road, Springfield, Va. 22151. Prices vary for paper\ncopy; $1.45 microfiche. Order by accession number, where given, in parentheses at end of each entry.\nWeather Bureau Technical Notes\nTN 41 EDL 1 Infrared Cloud Cover Detector. Ferdinand H. Zegel, May 1966. (PB-173-427)\nESSA Technical Memoranda\nWBTM EDL 2 Notes on Wind Measurement. Herman H. Crouser, August 1967. (PB-175-774)\nWBTM EDL 3 A Wind Vector Component Accumulator. Herman H. Crouser, December 1967. (PB-177-143)\nWBTM EDL 4 A Selective Precipitation Indicator. Richard C. Peck, July 1968. (PB-179-344)\nWBTM EDL 5 A Viscous Damped Wind Vane. D. T. Acheson and H. H. Crouser, October 1968. (PB-180-551)\nWBTM EDL 6 Winds Aloft Measurements Through LORAN C Navigation Aid. Christos Harmantas, October 1968.\n(PB-183-989)\nWBTM EDL 7 A Weather Data Radio Telemetry System. Robert R. Knibb and Francis V. Kohl, January 1969.\n(COM-74-10533)\nWBTM EDL 8 Video Integrator and Processor. Kenneth H. Shreeve, February 1969. (PB-183-510)\nWBTM EDL 9 Remote Readout Panel for a Digital Precipitation Gage. Francis V. Kohl, March 1969. (PB-\n183-056)\nWBTM EDL 10 Semiautomatic Computation of Rawinsondes. H. Dean Parry, October 1969. (PB-187-901)\nWBTM EDL 11 LORAN C Windfinding Capabilities: Wallops Island Experiments. D. T. Acheson, August 1970.\n(COM-71-00004)\nNOAA Technical Memoranda\nThe Acoustic ounder--Pollution Fighter's Tool. H. Dean Parry, April 1974. (COM-74-11401)\nNWS EDL 12\nEDL 13 Design and Operation of a Digital Video Integrator Processor (DVIP). Kenneth H. Shreeve,\nNWS\nMay 1974. (COM-74-11430)\n14 Radiosonde Frangibility Test (Radiosonde impact to Aircraft). Melvin J. Sanders and W.\nNWS EDL\nRay Price, March 1976. (PB-258423)\nA Microprocessor-Controlled Manual Entry Display. John D. Nilsen, March 1976. (PB-\nNWS EDL 15\n258422)","A\nQC\n851\nUGE4\nno.16\nNOAA Technical Memorandum NWS EDL 16\nNO-MOVING PARTS ANEMOMETER DESIGN ANALYSIS\nPROGRAM\nAnthony W. Cheek and Charles F. Lambert\nEquipment Development Laboratory\nSilver Spring, Md.\nOctober 1977\nATMOSPHERIC SCIENCES\nLIBRARY\nJAN\n1978\nN.O.A.A.\nU. S. Dept. of Commerce\nAND\nATMOSPHERIC\nAMOUNT NOAA\nNational Weather\nUNITED STATES\nNATIONAL OCEANIC AND\nService\nATMOSPHERIC ADMINISTRATION\nDEPARTMENT OF COMMERCE\nGeorge P. Cressman, Director\nRichard A. Frank, Administrator\nJuanita M. Kreps, Secretary\nCOMMUNITY\nOF\n78\n0174","","CONTENTS\nAbstract\n1\n1.\nIntroduction\n1\n2. Objectives\n1\n3. Summary\n2\n4.\nDescription of equipment\n4\n5. Test environments\n5\n5.1\nWind tunnel tests\n5\n5.1.1\nDescription of tests\n5\n5.1.2\nAnalysis of data.\n10\n12\n5.1.3\nConclusions\n5.1.4\nList of test equipment\n12\n5.2\nEnvironmental tests at Eglin A.F.B.\nClimatic Laboratory\n12\n5.2.1 Test sequence\n12\n5.2.1.1\nRime ice test\n14\n5.2.1.2\nRain test\n14\n5.2.1.3\nSolar radiation test\n14\n5.2.1.4\nRime icing test\n16\n5.2.2\nAnalysis of tests\n16\n5.2.3\nConclusions\n19\nTABLES\n1.\nRoot mean square errors from wind tunnel test data\n3\n-\nFIGURES\n1. - - J - TEC sensor and electronics\n6\n2. --E.I.I. series 100 crosswinds sensor and electronics\n7\n--Rosemount sensor and electronics\n3\n8\n4\n--J-TEC model VA-320 vaned anemometer\n9\n5\n-Anemometer arrangement\n13\n6.\n--Format of rain test\n15\n7.\n-- -Format of solar radiation test\n15\nNOTE: A11 dimensions shown on figures are in the SI system of\nmeasurement (Metric)\n.\niii","NO-MOVING PARTS ANEMOMETER\nDESIGN ANALYSIS PROGRAM\nAnthony W. Cheek and Charles F. Lambert\nEquipment Development Laboratory\nNational Weather Service, NOAA\nSilver Spring, MD 20910\nABSTRACT. The Equipment Development Laboratory recently tried\nfind a no-moving parts anemometer that would be satisfactory\nto\nfor marine applications, remote locations, and where icing\noccurs. Wind tunnel, rain, solar radiation, and rime ice\nformation tests were made for equipment accuracy and survival.\nNo single anemometer completely met the desired specifications,\nalthough improvements over earlier designs were noted in units\nthat were analyzed.\n1. INTRODUCTION\nThe National Weather Service (NWS) needs a no-moving parts amemometer for\nuse in marine applications, such as for Shipboard Environmental Data\nAcquisition System (SEAS) and Large Navigational Buoys (LNB's) ; in remote\nlocations; and where icing conditions occur. No-moving parts anemometers\nhave been evaluated under severe icing conditions for a number of years.\nSensors have been installed on top of Mammoth Mountain, Calif., in conjunc-\ntion with a Remote Automatic Meteorological Observing Station (RAMOS) that\nthe U.S. Forest Service uses for avalanche forecasting. Units that have been\npreviously evaluated include an ion-beam anemometer, a vortex shedding anemom-\neter, and a differential pressure orthogonal airspeed sensor. Results of\ntests on the last two sensors plus recent improvements were encouraging enough\nto start a new design analysis program. The vortex shedding units were pur-\nchased with a redesigned electronics package as were the differential\npressure sensors. Additionally, hot film sensors were purchased for evalu-\nation.\nThe analysis program consisted of testing candidate sensors in a wind\ntunnel to determine accuracy. Then a series of environmental tests involving\nrime ice, rain, and solar radiation were conducted while the units were\nmonitored for system changes. Finally, wind tunnel tests were run again to\ndetermine if there were any significant changes in the sensor accuracy\nbecause of the environmental tests or component aging.\n2. OBJECTIVES\nOur goal was to obtain a sensor that would operate in environments with\nextreme temperature, solar radiation, rain, and rime ice, with little or no","effect on sensor performance. The goals for range and accuracy were:\nRange\nAccuracy\n2 knots RMS or 5% RMS,\nWind speed\n0 to 120 knots\nwhichever is maximum\n0° to 360 O\n10° RMS\nWind direction\n3. SUMMARY\nBased on the results of the design analysis program, there is no single\nno-moving parts anemometer suitable to replace. the existing NWS anemometers\nthat meets the accuracy and environmental goals. The program results\nfollow.\n- All units survived the rime ice tests of 1/2 inch, 6 inch, and 12 inch/h\nicing rate (12.7 mm/h, 152.4 mm/h, and 304.8 mm/h, respectively); however,\nthe orthogonal airspeed sensor, the only heated sensor, was the only unit\nthat continued to function throughout these tests. The other sensor designs\nare not easily redesigned to incorporate heating elements.\n- During the rain tests, all anemometers functioned properly. However,\nafter the rain test the vortex shedding vaned anemometer, model VA-320,\n(not a true no-moving parts anemometer) produced erratic readings. Moisture\napparently migrated through the plastic connector, causing intermittent\nshort circuits.\n- Solar radiation affected the vortex shedding aluminum anemometer, model\nVT-1003. The voltage output increased and decreased throughout the test,\nindicating high wind speeds when essentially no wind was blowing. It appears\nthat the aluminum unit's electronics are sensitive to high temperatures.\nA summary of the wind tunnel RMS errors appears in table 1. The results\nof the wind tunnel tests before and after the environmental tests show:\n- The plastic vortex shedding anemometer, VT-1003, was within the allowable\nRMS error at 60 knots (111.12 km/h) and lower speeds. At 100 knots\n185.2 km/h) and above, the unit was out of tolerance.\n- The aluminum vortex shedding anemometer, VT-1003, was within tolerance\nof 60 knots (111.12 km/h) and lower speeds before the environmental tests.\nThe data after the tests indicate damage must have occurred because either\nspeed or direction was out of tolerance, except at 20 knots (37.04 km/h) and\n40 knots (74.08 km/h).\n- The first orthogonal airspeed anemometer was within the speed tolerance\nat 10 knots (18.52 km/h) through 60 knots (111.12 km/h) and exceeded the\ntolerance at 5 knots (9.26 km/h) and speeds higher than 100 knots\n(185.2 km/h).\n2","Dir.\nDeg.\n8.44\n4.33\n6.81\n3.75\n7.82\n6.20\n9.80\n6.49\n120 Knots\nSpeed\n11.54\n23.02\n7.35\n11.21\nKts.\n8.37\n8.71\n5.84\n6.76\nTABLE 1. ROOT MEAN SQUARE ERRORS FROM WIND TUNNEL TEST DATA\nDeg.\n6.47\n3.83\n3.56\nDir.\n4.27\n3.27\n4.03\n4.13\n5.22\n6.98\n7.11\n-\n-\n-\n100 Knots\nSpeed\n6.06\n11.54\n11.32\n2.67\n4.62\n5.49\n3.76\n15.82\n17.62\n3.18\nKts.\n5.17\n6.89\n7.17\n6.20\n3.47\nDir.\nDeg.\n3.47\n2.58\n5.99\n3.32\n3.11\n3.54\n5.38\n6.46\n-\n-\n-\n60 Knots\nSpeed\nKts.\n2.38\n2.32\n1.76\n1.95\n2.42\n6.50\n3.65\n3.59\n2.84\n2.32\n1.32\n9.52\n7.71\nDeg.\n3.67\n3.40\n3.63\n2.30\n4.32\n2.60\nDir.\n5.71\n3.27\n3.88\n4.71\n-\n-\n-\n40 Knots\nSpeed\nKts.\n2.04\n1.92\n1.18\n1.23\n0.52\n0.96\n2.79\n2.36\n2.05\n1.96\n1.22\n3.84\n5.42\n5.85\n7.58\nDir.\nDeg.\n3.33\n6.09\n3.33\n4.36\n3.36\n3.87\n4.64\n3.21\n-\n-\n-\n20 Knots\nSpeed\n1.63\n1.36\n1.36\n1.40\nKts.\n1.87\n1.33\n1.00\n2.44\n1.96\n1.68\n1.84\n1.44\n0.64\n12.57\n15.73\n16.37\n3.58\n6.43\n4.30\nDir.\nDeg.\n5.78\n5.80\n4.45\n4.83\n-\n-\n-\n10 Knots\nSpeed\n1.52\n0.66\n1.40\n1.80\nKts.\n1.65\n0.68\n0.52\n1.47\n1.46\n0.43\n1.17\n0.71\n0.77\n17.38\n16.10\n14.57\n11.21\n11.31\n17.41\n8.09\nDeg.\nSpeed Dir\n5 Knots\n-\n-\n-\n2.33\n0.30\nKts.\n0.46\n0.98\n0.92\n0.75\n0.95\n0.89\n0.73\n1.71\nAFTER EGLIN TEST, , 2-77\nAFTER EGLIN TEST, , 2-77\nAFTER EGLIN TEST, , 2-77\nBEFORE EGLIN TEST,\nBEFORE EGLIN TEST,\nBEFORE EGLIN TEST, ,\nVORTEX VANE, 2-77\nALUMINUM VORTEX\nPLASTIC VORTEX\nORTHOGONAL #1\n4 WIRE CAGE\nORTHOGONAL #2\n20 WIRE CAGE\nst RUN, , 1 -77\nnd RUN ,2-77\n3rd RUN,3-77\n4 RUN 4-77\nANEMOMETER\nHOT FILM,\nVA-320\n3-76\n10-76\n10-76\n10-76\nth\n2\n1\n3","- The second orthogonal airspeed anemometer, with the design modification,\nshowed improved low speed accuracy compared to the first unit. An average\nof the four runs taken approximately a month apart indicates the RMS speed\nerror was within tolerance except at 120 knots (222.24 km/h) and the\ndirection error was out of tolerance only at 5 knots (9.260 km/h).\n- The vortex shedding vaned anemometer, VA-320, was out of tolerance above\n40 knots (74.08 km/h). The direction error was in tolerance except at the\n0° position where a 4° dead band exists.\n- The hot film, single component anemometers were out of tolerance at all\nspeeds above 40 knots (74.08 km/h).\n4. DESCRIPTION OF EQUIPMENT\nThe anemometers used in the analysis program were:\nJ-TEC Associates, Inc.\nVortex shedding anemometer\n317 Seventh Ave., S.E.\nCedar Rapids, Iowa 52401\nEnvironmental Instruments, Inc.\nHot film anemometer\n7 Erie Drive\nNatick, Mass. 01760\nOrthogonal airspeed sensor\nRosemount, Inc.\n(differential pressure)\nP.O. Box 35129\nMinneapolis, Minn. 55435\nThree vortex shedding anemometers were tested during the program. Two of\nthem were the VT-1003 series (fig. 1) and the third unit was the VA-320\n(fig. 4)\nThe two hot film units were the series 100, single component, cross wind\nsensors, one with a 4 wire cage enclosure and the other with a 20 wire cage\nenclosure (fig. 2)\nThe two orthogonal airspeed sensors (differential pressure transducers)\nwere ordered as identical units (fig. 3). However, as testing progressed,\nthe second unit was modified to improve the low speed accuracy.\nThe three vortex shedding anemometers used an ultrasonic beam to sense\nthe vortices in the air flowing past a rod or strut in a tube. The frequency\nof the vortices was proportional to the air velocity.\nTwo of the vortex shedding anemometers, both model VT-1003 series, were\nidentical in design, except that one sensor head was made of Lexan plastic\nwhile the other was made of aluminum. Each of these sensors had six tubes\nplaced 60° apart, contained no moving parts, and had no heater for deicing.\nFrom a sensor head, seven BNC cables were connected to an electronics box\nthat produced two voltages. The fore and aft axis of the sensor was given\nby one voltage and the axis perpendicular to the fore and aft, or left and\n4","right, axis was given by the other voltage. The output voltage range was\n0 to + 5.7 VDC for winds of 0 to 120 knots (222.24 km/h). It should be\nnoted that the electronics, as purchased, are only suitable for laboratory\nuse. The equipment was repackaged by the Equipment Development Laboratory so\nthat it could be exposed to the environmental parameters. Both sets of\nelectronics, a power supply, terminal board, and switches were housed in a\nseparate enclosure for testing.\nThe third vortex shedding sensor, model VA-320, relied on a moving vane to\nindicate direction by aligning itself with the direction of the wind. After\nalignment was achieved, wind speed was sensed by a single tube in the vane\nthat operated exactly like the tubes in the VT-1003 series. This vaned\nanemometer was also unheated. The electronics were located just below the\nvane and transmitted the speed in frequency and direction in DC volts.\nBoth of the hot film anemometers used a precision heat loss wind sensor to\nsense wind speed in one direction. A dual component unit was available to\ndetermine wind direction but was not needed to test the accuracy of the\nanemometer's design. The hot film anemometer's electronics unit generated\nan output signal from 0 to + 10 VDC from a cabled signal received from the\nsensor. Neither the 4 wire nor the 20 wire cages were heated to prevent ice\nformation.\nThe two orthogonal airspeed anemometers had the only heated sensors among\nthe group tested. The sensor is simple, slender, cylindrical, rugged, and\nlends itself to efficient heating to prevent ice formation. The heating\nelement had a self-regulating power consumption feature to extend the life\nof the sensor by decreasing the power by 100 watts during still air\nconditions.\nThe orthogonal airspeed sensor had four pneumatic outputs that must be\npiped to a capacitive pressure transducer, which converts the pressure\nsignals into two voltages. One voltage was for the fore and aft axis, and\nthe other was for the left and right axis, much the same as in the vortex\nshedding anemometer, VT-1003 series. The orthogonal airspeed anemometer had\na different speed conversion factor and the output voltage range was 0 to\n+ 9.6 VDC over a wind speed range of 0 to 120 knots (222.24 km/h). The\northogonal airspeed anemometer consisted of a heated cylindrical sensing\nprobe, transducer electronics, power supply, switches, drain tubes (for\ningested water) and waterproof enclosure. The heated probe and transducer\nwere purchased as individual components and repackaged by the Equipment\nDevelopment Laboratory along with the other components in a suitable enclo-\nsure.\n5. TEST ENVIRONMENTS\n5.1 Wind Tunnel Tests\n5.1.1 Description of Tests\nTwo orthogonal airspeed anemometers, three vortex shedding anemometers, and\ntwo hot film anemometers were tested at the Test and Evaluation Division\n5","CABINET IS 237.30 DP.\nf\nO\nO\n0\no\nELECTRONICS\n208.00\n355.6\n+\n11.20 DIA\n208.0 LG.\nHEX HD. SCREW\nNO. 1 4 - 20 UNC\nAPPROX\nCABLE\n106,43 DIA\n1\"A\"\n2 REQ.\n276.23 DIA\n®\nEA\nVIEW\"A-A\"\n165.10\nSUPPORT\nSENSOR\n4 HOLES\n5.15 DIA","SENSOR\n8.00 DIA\nELECTRONICS\n4 HOLES\n⑉\n171.45\nSUPPORT\n+\nI\nNO. 4 - 20 UNC\nHEX HD. SCREW\nSIGNAL\n2 REQ.\nINPUT\n28V\n5.10 DIA\n4 HOLES\nCABLE APPROX.\n165.10\n10 M\n152.40\n106.43\n+\n$2.23\nDIA\n52.83\n9.65\n111.25\n190.50\nFig. 2 E.I.I. SERIES 100 CROSSWINDS SENSOR & ELECTRONICS\n7","SENSOR PORTS\n13.50 DIA\n4 HOLES\n355.60\n171.50\n419.10\n69.85\nFig. 3 ROSEMOUNT SENSOR & ELECTRONICS\n8","2270","(T&ED) in Sterling, Va. All tests were performed in the large wind tunnel,\nexcept the 5-knot (9.26 km/h) test for the vane, plastic (Lexan), and\naluminum vortex shedding anemometers, which were performed in a smaller wind\ntunnel. The air velocity in the large tunnel was calculated using a pitot\ntube (readings in inches of alcohol) with corrections made for temperature,\nspecific gravity, pressure, and pitot tube correction factors to equal the\ncalibration of the National Bureau of Standards' (NBS) pitot tube. The\nmaximum error due to the proximity of the pitot tube to that of the sensors\ntested was found to be less than 0.6%. The anemometers were rotated from\n0° to 360° in 15° increments. The nominal wind speeds were 5, 10, 20, 40,\n60, 100, and 120 knots (9.26, 18.52, 37.04, 74.08, 111. 12, 185.20, and\n222.24 km/h) except for the hot film sensors, which were not tested at\n120 knots.\nAll 5-knot tests were performed separately during the most stable\nconditions. The tests at other speeds were performed in increasing order\nfrom 10 to 120 knots. At each 90° interval, a check for hysteresis effect\nwas made by increasing, then decreasing the wind speed.\nThe hot film and vortex shedding anemometers were tested at 5 knots in the\nsmall wind tunnel, where a hot-wire anemometer, with a maximum possible error\nof 13% at 5 knots, was used to determine air velocity. Calibration of the\nhot-wire anemometer ranged from 3 to 13% maximum with two independent source\ncalibrations. It is not known which is correct at this time. Therefore,\nthis error has not been included in the calculations at 5 knots for the\nvortex shedding and hot film anemometers only. At all other speeds\ncorrections have been incorporated. The small wind tunnel, designed for\nspeeds below 10 knots, was used rather than the larger tunnel because the\nsmall tunnel has a more laminar flow at the lower speeds, allowing better\ndetermination of wind direction. Both orthogonal airspeed anemometers were\ntested in the large tunnel at 5 knots because of the size of the unit and\nmounting problems in the smaller tunnel.\n5.1.2 Analysis of Data\nAnalysis of the root mean square (RMS) errors of speed and direction show\nthat none of the anemometers tested are completely within the NWS speed and\ndirection requirements of 2 knots RMS (3.70 km/h) or 5% RMS, whichever is\nlarger from 0° to 360°,\nA minimum of 25 data points was used for each RMS error calculation. The\nRMS errors were calculated by first squaring the difference between the\nactual wind speed and the wind speed calculated from the output voltages of\nthe anemometers, summing these squared values, dividing by the number of\nsquared values, and then taking the square root of the quantity. The output\nvoltages were sampled by a calculator at a rate of five times a second for\n2 seconds after the tunnel airspeed had settled, which allowed the anemom-\neters plenty of time to respond to the airspeed. These output voltages were\nmeasured with multimeters accurate to 0.002% of the value read which ranged\nfrom 0.000 to 10.000 volts. Several sources of error are inherent in the\nanemometer systems; for example, span, linearity, resolution, etc. For the\nvortex shedding vaned anemometer, the combined error due to these error\n10","sources was stated to be less than 1% RMS of full scale, threshold to 156\nknots (288. 02 km/h), for speed, and + 1.9° error for direction. For the\nvortex shedding tube type anemometers, the combined speed error was stated\nto be 2.7% with a direction error of 2.5° For the orthogonal airspeed\nanemometers a 2.9% error was assumed inherent in the system for both wind\nspeed and direction combined.\nThe plastic vortex shedding anemometer was the only anemometer whose speed\nand direction were within requirements at 5 knots (9.26 km/h), but fell short\nof requirements at speeds near 100 knots (185.20 km/h) and above. The\naluminum vortex shedding anemometer was out of directional requirements at\n60\nknots (111.12 km/h) and above. Both of the vortex shedding tube\nanemometers appeared to have lost some low speed directional accuracy below\n20 knots (37.04 km/h) after the environmental tests at Eglin Air Force Base.\nOf the two orthogonal airspeed anemometers, the second orthogonal airspeed\nsensor was the most promising over the entire speed range. A design\nmodification had been incorporated in the second sensor to improve the low\nspeed accuracy. The first sensor had a larger directional and speed error\nat lower speeds, below 20 knots (37.04 km/h), while the second sensor lost\ndirectional accuracy at 5 knots (9.26 km/h) and below. The second sensor\nwas tested in the wind tunnel four times because of its promising performance\nover the entire speed range and the fact that its RMS speed errors bordered\nnear the limits of the maximum allowable RMS speed errors of the require-\nments. As each test was performed the method of testing improved and the\nanemometer's accuracy improved overall. The speed error of the last test\nwas well within speed requirements except at 120 knots, when the RMS speed\nerror was 7.35 knots (13.61 km/h). The directional error was satisfactory\nexcept at 5 knots where a 17.41° RMS error existed.\nTaking the RMS errors of both speed and direction of all four tests of the\nsecond sensor produces the following:\nKnots\n5\n10\n20\n40\n60\n100\n120\nRMS speed error\n1.07\n1.92\n2.16\n0.85\n2.67\n4.26\n8.05\nRMS direction error\n15.02\n5.25\n3.81\n3.70\n4.85\n5.99\n7.71\nThe RMS speed error exceeded the requirements slightly at 40 and 120 knots\nand exceeded the direction requirements at 5 knots.\nThe vortex shedding vaned anemometer responded much like the vortex\nshedding tube anemometers by exceeding speed requirements at speeds above\n60 knots. The direction test of the vaned vortex shedding anemometer showed\na dead spot around the 0° to 4° area, but read properly elsewhere in the\n0° to 360° range.\nThe hot film sensors were within tolerance at speeds of 20 knots\n(37.04 km/h) and below. However, at the higher speeds of 40 knots and above,\nthe output test curves of both sensors appeared to have a flat and widening\narea near the peaks of the ideal curves that looked like a distorted square\nwave curve rather than a sine curve.\n11","Both hot film sensors were returned to the company in April 1976 to be\nrecalibrated to improve the higher speed response and have not been returned\nas of May 1977. Judging from this long wait, the fix is not a simple\nrecalibration but appears to be a major design change.\n5.1.3 Conclusions\nThe plastic vortex shedding anemometer was better at speeds below 100 knots\n(185.20 km/h), although there was a decrease in the directional accuracy\nafter the environmental tests. This loss of accuracy was more noticeable\nin the aluminum unit, which was specified to be the same design as the plas-\ntic unit except for the anemometer's sensor head being aluminum rather than\nLexan plastic. Neither vortex shedding anemometer, VT-1003, was accurate\nabove 100 knots (185.20 km/h).\nThe vaned anemometer, model VA-320, (not truly a no-moving part amemometer)\nwas in tolerance at low speeds but exceeded the requirements at 40 knots\n(74.08 km/h) and higher speeds. Over the complete range of speeds the\nsecond orthogonal airspeed anemometer more closely approached the require-\nments, but still needs refinements in the mid-range speeds and in direction\nat lower speeds around 5 knots (9. 26 km/h) The second orthogonal airspeed\nanemometer is a modified model of the first unit. It achieves the low\nspeed accuracy. The second unit was not available for the Eglin tests.\nTesting of the hot film sensors was terminated because the vendor was\nunable to modify the units so they would perform adequately. Preliminary\ndata indicate they were within tolerance below 20 knots.\n5.1.4 List of Test Equipment\n1. Hewlett-Packard calculator model #9810 sampling output voltages\n5 times per second for 2 seconds, then averaging.\n2. Quartz pressure manometer model #10100-001 with pressure sensor\nmodel #10095-002 accurate to less than 0.004 inches.\n3. Rosemount temperature sensor, probe model #M104B and linear\nbridge model # 420 LS, accurate to less than 0.2°C.\n4. Systron Donner multimeter model #7004 accurate to within 0.02% of\nthe reading used to measure output of temperature sensor.\nTwo Dana multimeters model #5900 accurate to within 0.002% of\n5.\nthe reading used to measure output voltages of anemometers.\n5.2 Environmental Tests at Eglin A.F.B. Climatic Laboratory\n5.2.1 Test Sequence\nThe anemometers were subjected to the following tests in the order listed.\nSee figure 5 for the anemometer arrangement.\n12","J - TEC VA-320\nJ-TEC MODEL VT-1003\n(ALUMINUM)\n38.00\n45° N\nJ-TEC MODEL VT-1003\n190.00\n(PLASTIC)\n45°\nN\nN\n45\n381.00\n356.00\nJ-TEC ELECTRONICS\nENCLOSURE DURING\nSOLAR RADIATION\na\n657.00\nSENSING\n410.00\nPORTS\n210.00\n400.00\nTOP SURFACE OF ROSEMOUNT\n& J - TEC ENCLOSURE DURING\nSOLAR RADIATION TEST\nROSEMOUNT\nENCLOSURE\nFig. 5 ANEMOMETER ARRANGEMENT\n13","5.2.1.1 Rime Ice Test\nRime ice tests were made at 1/2-inch/h (12.7 mm/h) and 6-inch/h\n(152.4 mm/h) rates and the anemometers were exposed to the following:\n- Low wind speed, 20 knots (37.0 km/h), calibration check.\n- High wind speed, 50 knots (92.6 km/h) calibration check.\n- 1/2 inch/h rime icing for 66 minutes.\n- High wind speed calibration check.\n- 6 inch/h rime icing for 46 minutes.\n- Minimum voltage test on the heater of the orthogonal airspeed sensor at\n1/2-inch/h rime icing rate.\n- High wind speed calibration check.\n- Minimum voltage test on the heater of the orthogonal airspeed sensor at\n6-inch/h rime icing rate.\n5.2.1.2 Rain Test\nA rain test was made in accordance with MIL-STD-810C, METHOD 506.1,\nPROCEDURE I, and figure 6. The rainfall rates were 3 inch/h (76.2 mm/h)\nand 5 inch/h (127.0 mm/h), and the anemometers were exposed to the following:\n- Low wind speed calibration check.\n- High wind speed calibration check.\n- 3-inch/h rain rate with no forced air for 6 minutes.\n- 3-inch/h rain rate with high wind speed for 4 minutes.\n- 5-inch/h rain rate with high wind speed for 5 minutes.\n- 3-inch/h rain rate with high wind speed for 6 minutes.\n- 3-inch/h rain rate with no forced air for 11 minutes.\n5.2.1.3 Solar Radiation Test\nThe solar radiation test was conducted in accordance with MIL-STD-810C,\nMETHOD 505.1, and PROCEDURE II. The test was limited to one, 6-hour cycle,\n(3 level) of controlled simulated solar radiation (figure 7). The 1st level\nof solar radiation (LSR) was 3.62 W/m2; the 2nd LSR was 7.15 W/m2 and the\n3rd LSR was 9.76 W/m2. The anemometers were tested as follows:\n14","74.1 km/h WINDS\n127.0\n76.2\n25.4\no\n5\n10\n15\n20\n25\n30\nTEST TIME (MINUTES)\nFig. 6 FORMAT OF RAIN TEST\n+ - 37.0 km/h WIND CALIBRATION CHECKS\nSOLAR RADIATION\nPROFILE\n9.76\n+\n+\n49,0\n7.15\n+\n+\nCHAMBER TEMPERATURE\n43.3\nPROFILE\n3.62 €\n+\n+\n37.8\n32.2\n70\n130\n190\n250\n310\n350\nTEST TIME (MINUTES)\nFig. 7 FORMAT OF SOLAR RADIATION TEST\n15","- Low wind speed calibration check.\n- 1st LSR for 70 minutes.\n- 2nd LSR for 60 minutes.\n- 3rd LSR for 120 minutes.\n- 2nd LSR for 60 minutes.\n- 1st LSR for 40 minutes.\n5.2.1.4 Rime Icing Test\nRime ice tests were conducted at 12-inch/h (304. 8 mm/h) rate at -32° to\n-34°C and the anemometers were exposed to the following:\n- High wind speed calibration check.\n- Minimum voltage test on the heater of orthogonal airspeed sensor at\n12.inch/h rime icing rate.\n- 12 inch/h rime icing for 60 minutes.\n- High wind speed calibration check after rime icing was stopped and again\nafter ice was removed from anemometers.\n5.2.2 Analysis of Tests\nBefore each test, a wind speed calibration check was taken for a compara-\ntive wind speed and direction figure, since various racks and frames for\ncreating rain and rime ice were used on the wind machine during the\ndifferent tests. These variations and a nonlaminar wind machine produced\na varying wind source from test to test.\nThe 1/2-inch/h rime ice rate was not uniform for all anemometers. During\nthe early part of the test, the orthogonal airspeed sensor was receiving a\n1/2-inch/h (12.7 mm/h) rate but the two vortex shedding sensors, model\nVT-1003, were receiving about 1/4-inch/h (6.4 mm/h) rate and the vane, model\nVA-320, received approximately 1/8 inch/h (3.2 mm/h). The icing machine was\nadjusted about half way through the test to produce a uniform 1/2-inch/h\nrate for all anemometers. Because of this problem, all three vortex shedding\nsensors did not ice up as quickly as they would have with a continuous uniform\n1/2-inch/h rate.\nThe wind machine was nominally set at 53 knots (98.16 km/h). During the\ntest, the aluminum, VT-1003, - unit showed an error of 30 knots (55.56 km/h)\nafter 8 minutes of icing. The plastic, VT-1003, and vaned, VA-320, units\nwere next to show substantial speed errors of 20 and 10 knots (37.04 and\n18.52 km/h) respectively after 27 minutes of icing. The orthogonal airspeed\nunit's output speed dropped by 5 to 7 knots (9.26 to 12.96 km/h) after 54\nminutes of icing. This decreased speed continued throughout the 1/2-inch/h\n16","rime ice test and was the result of a speed variation in the wind machine\nused to create the rime ice, as there was no ice build up on the orthogonal\nairspeed sensor. All the vortex shedding anemometers continued to decrease\nin air speed as ice formed around the sensing tubes or ports, dropping the\nindicated air speed to 3 to 5 knots (5.56 to 9.26 km/h)\nAfter the 1/2-inch/h rime ice test, the anemometers were cleared of ice\nwith cold water. A high wind speed calibration check was taken which\nrevealed a 13.5.knot (25.0 km/h) drop in the air speed of the aluminum,\nVT-1003, unit as compared with the calibration check taken before the 1/2-\ninch/h rime ice test. All the other anemometers were close to the original\nvalues except the vaned, VA-320, unit which did not recover after the ice was\nremoved. Later, before the rain test, the problem with the vaned unit was\ndiscovered to be faulty crimped pins in the connector, which were repaired.\nIn the first 7 minutes of the 6-inch/h (15.24 mm/h) rime ice test both\nvortex shedding, VT-1003, anemometers registered 21 knots (38.89 km/h)\ninstead of 53 knots (98.16 km/h). After 18 minutes of icing, all of the\nvortex shedding sensors were visibly covered with ice, while the orthogonal\nairspeed anemometer was operating properly with no apparent icing. The\n6-inch/h rime ice test lasted 46 minutes and the orthogonal airspeed sensor\nremained free of ice, while the vortex shedding sensors were completely\ncovered and nonfunctioning.\nUnder the minimum voltage test at 6-inch/h rime ice rate, the heater volt-\nage of the orthogonal airspeed sensor was gradually dropped from 115 VAC to\n69 VAC and the power dropped from 250 watts to 124 watts. At a 6-inch/h\nrime icing rate, 69 VAC was the minimum voltage at which the orthogonal air-\nspeed sensor remained ice free. After being completely cleared of ice, all\nthe anemometers remained overnight in a 5°C chamber.\nBefore the 1/2-inch/h rime ice minimum voltage test, a high wind speed\ncalibration check revealed a 7-knot (12.96 km/h) decrease in the aluminum,\nVT-1003, unit's wind speed and a 12° direction error compared to a 1.42°\ninitial calibration error. During the minimum voltage test on the orthogonal\nairspeed sensor's heater at a 1/2-inch/h rime icing rate, the voltage was\nlowered to 67 VAC and 114 watts without ice forming around the sensing ports.\nFor the rain test a rack with nozzles was placed above the anemometers and\none in front of the wind machine to produce driving rains. This lowered the\nhigh wind speed by approximately 10 knots (18.52 km/h) during the wind speed\ncalibration check before the rain test. A11 the anemometers performed\nproperly throughout the rain test. After the rain test the anemometers were\nblown dry and left overnight in the chamber at 15°C.\nThe next test was the solar radiation test using a 6 X 12 rack of 75 watt\nbulbs mounted approximately 3.8 meters above the ground. Radiation measure-\nments were taken at the top of the aluminum, VT-1003, sensor approximately\n2 meters from the rack of bulbs. Three different levels of solar radiation\n(LSR) were produced; the first level at 3.62 W/m2, the second level at 7.15\nW/m2, and the third level at 9.76 W/m2. After 13 minutes of the 1st LSR, the\nindicated speed of the aluminum unit increased to 63 knots (116.7 km/h) in\n17","the south direction when no more than 5-knot (9.26 km/h) winds existed in the\nchamber. The temperature in the chamber was 34.0°C and 36.8°C in the elec-\ntronics box of the vortex shedding, VT-1003, units. This condition continued\nuntil a low wind speed calibration check was taken 41 minutes into the test,\nwhen all anemometers read proper wind speeds. After the calibration check,\nthe aluminum unit continued to indicate very high wind speeds.\nAfter 70 minutes of the 1st LSR, the 2nd LSR was applied. The indicated\nspeed of the aluminum unit dropped from 72 knots (133.3 km/h) to 9 knots\n(16.67 km/h) then fluctuated between values of 30 knots (55.56 km/h) and\n9 knots. This fluctuation continued until another low wind speed calibration\ncheck was performed. A11 anemometers read properly except the vaned unit,\nVA-320, which read 8 knots (14. km/h) with a 20-knot (37.04 km/h) wind.\nAfter the calibration check and until the end of the 2nd LSR all the\nanemometers read properly.\nAt the start of the 3rd LSR, the output of the aluminum unit jumped to\n103.2 knots (191.1 km/h) with less than 5 knots (9.26 km/h) of wind in the\nchamber. Then it dropped to 2.14 knots (3.96 km/h). The chamber temperature\nwas -47.1°C and the vortex shedding unit's electronics box was 51.2°C. The\nspeed fluctuation continued throughout the solar radiation test and always\nstopped when a low wind speed calibration check was made in which all\nanemometers read properly. Near the end of the higher LSR, which lasted 2\nhours, the thermocouple measuring the temperature inside the electronics box\nof the vortex shedding units was moved to a position between the power supply\nand the aluminum unit's electronics. At the end of the higher LSR, the\nhighest temperature recorded inside the electronics box was 69.3°C with a\n48.4°C chamber temperature.\nAfter the end of the higher LSR, the 2nd and 1st LSR were each applied for\n1 hour. The aluminum unit continued to fluctuate except during the low wind\nspeed calibration tests. The entire solar radiation test lasted about 6\nhours. After the test, a low wind speed calibration check was performed and\nall anemometers read properly. The anemometers remained in the chamber until\n3:00 a.m. when the temperature was dropped to -32°C in preparation for the\n12-inch/h (304.8 mm/h) rime ice test and minimum voltage test.\nBefore the 12 inch/h rime icing began, a high wind speed calibration test\nwas performed. The aluminum unit was reading 10 knots (18.52 km/h) lower\nthan the other anemometers and also had a considerable directional error of\n14°\nThe orthogonal airspeed sensor's heater in the minimum voltage test was\nfirst set at 70 VAC and 126 watts with 12 inch/h (304.8 mm/h) rime icing.\nGradually, the voltage was raised as ice began to form around the sensing\nports. The minimum voltage where ice would not form was 85 VAC and 150\nwatts. During the minimum voltage test at the 12-inch/h rime icing rate\nboth the aluminum and plastic vortex shedding anemometers dropped in speed\nby 10 and 30 knots (18.52 and 55.56 km/h), respectively, after 4 minutes of\nicing. After 8 minutes of icing, all the vortex shedding sensors were\ncovered with ice, closing the openings facing the icing machine. The\northogonal airspeed sensor remained free of ice throughout the minimum\n18","voltage test, which lasted 16 minutes.\nThe voltage on the orthogonal airspeed sensor was increased to 115 VAC and\n250 watts after the minimum voltage test, and remained at this voltage\nthroughout the 12-inch/h (304.8 mm/h) rime ice test. A small piece of ice\nbegan forming around some of the sensing ports and distorted the wind direction\nafter 20 minutes of icing. Two minutes later, the indicated wind speed\ndropped 10 knots (18.52 km/h) due to the small piece of ice. Throughout the\nrime ice test, ice would start to form around the sensing ports, build up to\na piece approximately 3/16-inch X 1/4-inch X 1/2-inch long (4.76 mm X\n.35 mm X 12.7 mm), but would always melt and blow away within a minute to a\nminute and a half. After 39 minutes of rime icing, there was one instance\nof a 1/2-inch wide (12.7 mm) ring that blocked the sensing ports and dropped\nthe wind speed to 10.3 knots (19.08 km/h) for only 6 seconds. The heater\nmelted the ice and the ring slid to the bottom of the sensing tube. After\n48 minutes of rime icing, the worst case of prolonged speed error occurred\nfor less than 2 minutes. Within this time interval, the indicated wind speed\ndropped over 20 knots (37.04 km/h) due to ice that blocked sensor ports.\nThroughout the rest of the 12-inch/h (304.8 mm/h) rime ice testing, which\nlasted 1 hour, ice would start to form around the sensing ports, melt and\nblow away in cycles of a minute to a minute and a half.\nAfter the test was completed, the ice was cleared off all anemometers and\nthe temperature was raised to approximately room temperature. A high wind\nspeed calibration test was performed in which all the anemometers' outputs\nread very close to the values at the start of the testing.\n5.2.3 Conclusions\nThe 1/2-inch/h rime icing test established that all the vortex shedding\nanemometers were not very useful during these icing conditions. The\northogonal airspeed anemometer operated properly throughout the 1/2-inch/h\nand 6-inch/h rime icing test. The icing test affected the aluminum vortex\nshedding anemometer, resulting in a 13.5-knot (25.0 km/h) decrease in the\nhigh wind speed calibration check taken after the ice was cleared from the\nsensors. This fault showed up again the following day during another cali-\nbration check before the minimum voltage test at a 1/2-inch/h rime icing\nrate. Under a 12-inch/h rime icing rate, the orthogonal airspeed anemometer\nsuffered short term speed errors due to icing, lasting less than 2 minutes.\nThroughout the rain test all the anemometers performed properly. After\nsoaking overnight in a damp chamber, the vaned vortex shedding anemometer,\nVA-320, began to give erratic readings, possibly due to incorrect crimping\nof the wires to the connector pins and moisture from the chamber.\nThe fluctuation that occurred during the solar radiation test with the\naluminum vortex shedding unit was determined to be a faulty electronics\nunit. After switching the plastic and aluminum sensor heads, the problem of\nunusually high wind speed readings appearing with little or no winds still\noccurred at the output of the aluminum electronics unit. This problem seemed\nto start once the temperature inside of the vortex shedding units reached\n39.1°C, implying a temperature sensitive electronics unit. Since both the\n19","plastic and aluminum vortex shedding electronic units are the same design,\nit appears that the aluminum unit had defective components.\nThe minimum voltage test produced valuable data on the minimum power\nneeded to keep the orthogonal airspeed sensor ice free. At least 150 watts\nat 85 VAC was needed to keep a 12-inch/h rime icing rate from blocking the\nsensing ports of the sensor. This was a 100-watt reduction from the maximum\nnormal power requirement of 250 watts at 115 VAC. The orthogonal airspeed\nunit was the only anemometer to operate properly under prolonged icing\nconditions. Its maximum power requirement was approximately 12 times that\nof either of the vortex shedding anemometers, VT - 1003. With the power\nreduced to 150 watts, the orthogonal airspeed unit's requirement was 7.5\ntimes that of one vortex shedding anemometer.\n20","NOAA CENTRAL LIBRARY\nCIRC QC851.U6 E4 no.16\nCheek, Antho No-moving parts anemometer\n3 8398 0002 1641 0\nNOAA SCIENTIFIC AND TECHNICAL PUBLICATIONS\nNOAA, the National Oceanic and Atmospheric Administration, was established as part of the Depart-\nment of Commerce on October 3, 1970. The mission responsibilities of NOAA are to monitor and predict the\nstate of the solid Earth, the oceans and their living resources, the atmosphere, and the space environment of\nthe Earth, and to assess the socioeconomic impact of natural and technological changes in the environment.\nThe six Major Line Components of NOAA regularly produce various types of scientific and technical\ninformation in the following kinds of publications:\nTECHNICAL SERVICE PUBLICATIONS-These -\nPROFESSIONAL PAPERS - Important definitive\nare publications containing data, observations, in-\nresearch results, major techniques, and special in-\nstructions, etc. A partial listing: data serials; pre-\nvestigations.\ndiction and outlook periodicals; technical manuals,\nTECHNICAL REPORTS-Journal quality with ex-\ntraining papers, planning reports, and information\ntensive details, mathematical developments, or data\nserials; and miscellaneous technical publications.\nlistings.\nTECHNICAL MEMORANDUMS - Reports of\npreliminary, partial, or negative research or tech-\nATLAS-Analysed data generally presented in the\nnology results, interim instructions, and the like.\nform of maps showing distribution of rainfall, chem-\nical and physical conditions of oceans and atmos-\nCONTRACT AND GRANT REPORTS-Reports\nphere, distribution of fishes and marine mammals,\nprepared by contractors or grantees under NOAA\nionospheric conditions, etc.\nsponsorship.\nAND NOAA ATMOSPHERIC\nInformation on availability of NOAA publications can be obtained from:\nENVIRONMENTAL SCIENCE INFORMATION CENTER\nENVIRONMENTAL DATA SERVICE\nNATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION\nU.S. DEPARTMENT OF COMMERCE\nNOAA--S/T 77-2924"]}