Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Filetype[PDF-1.64 MB]



Details:

  • Journal Title:
    Analytical and Bioanalytical Chemistry
  • NOAA Program & Office:
  • Description:
    Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives of this study were to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for multi-class steroid hormone detection using biologically relevant concentrations, then test limits of detection (LOD) in a high-background matrix by spiking charcoal-stripped fetal bovine serum (FBS) extract. Accuracy was tested with National Institute of Standards and Technology Standard Reference Materials (SRMs) with certified concentrations of cortisol, testosterone, and progesterone. 11-Deoxycorticosterone, 11-deoxycortisol, 17-hydroxypregnenolone, 17-hydroxyprogesterone, adrenosterone, androstenedione, cortisol, corticosterone, dehydroepiandrosterone, dihydrotestosterone, estradiol, estriol, estrone, equilin, pregnenolone, progesterone, and testosterone were also measured using isotopic dilution. Dansyl chloride (DC) derivatization was investigated maintaining the same method to improve and expedite estrogen analysis. Biologically relevant LODs were determined for 15 hormones. DC derivatization improved estrogen response two- to eight-fold, and improved chromatographic separation. All measurements had an accuracy a parts per thousand currency sign14 % difference from certified values (not accounting for uncertainty) and relative standard deviation a parts per thousand currency sign14 %. This method chromatographically separated and quantified biologically relevant concentrations of four hormone classes using highly specific fragmentation patterns and measured certified values of hormones that were previously split into three separate chromatographic methods.
  • Source:
    Analytical and Bioanalytical Chemistry, 408(15), 4179-4190.
  • Document Type:
  • Rights Information:
    Accepted Manuscript
  • Compliance:
    Submitted
  • Main Document Checksum:
  • File Type:

Supporting Files

  • No Additional Files

More +

You May Also Like

Checkout today's featured content at repository.library.noaa.gov

Version 3.26